Overview
Johnson Controls - Largo Plant is a cooling tower facility in Largo, Florida, United States. It operates under NAICS code 333415 for air-conditioning and warm air heating equipment manufacturing.
Johnson Controls - Largo Plant is a cooling tower facility located at 8575 Largo Lakes Dr, Largo, Florida, United States. The facility is operational and falls under NAICS code 333415, which covers air-conditioning and warm air heating equipment manufacturing. As part of a global leader in building technologies, this plant plays a role in the production and maintenance of cooling infrastructure. The facility operates within the regulatory framework of the United States, which includes adherence to ASHRAE 15 for refrigeration safety and the Kigali Amendment to the Montreal Protocol for refrigerant management. Cooling towers in this region typically use evaporative cooling, which requires significant water consumption, and are designed to achieve high operational efficiency (COP) to minimize energy use. Environmental considerations for cooling towers include refrigerant global-warming potential (GWP) and water usage. Johnson Controls is known for incorporating sustainable practices, such as using low-GWP refrigerants and optimizing water efficiency. The plant's location in Florida, a state with high cooling demand, underscores its importance in supporting local climate control and industrial processes.
Environmental context
Cooling towers in Florida operate in a humid subtropical climate, where evaporative cooling is common but requires substantial water resources. The facility likely uses water treatment to minimize scale and biological growth, reducing environmental impact. Refrigerant management is critical, with regulations phasing down high-GWP refrigerants under the Kigali Amendment. Energy efficiency (COP) is a key metric, as cooling towers account for a significant portion of building energy use.
Frequently asked questions
Johnson Controls - Largo Plant is located at 8575 Largo Lakes Dr, Largo, Florida 33773-4910, United States.
It is a cooling tower facility classified under NAICS code 333415 for air-conditioning and warm air heating equipment manufacturing.
The facility is operational.
Cooling towers in the US must comply with ASHRAE 15 for refrigeration safety and the Kigali Amendment to the Montreal Protocol for refrigerant phase-down.
Key factors include refrigerant global-warming potential (GWP), water consumption for evaporative cooling, and operational efficiency (COP).
Other Cooling Tower plants in United States · 6 nearby