Gas Pipeline Operational

Trunkline Gas Company LLC TGCS Relay for Proposed I-269 - Byhalia, Mississippi Gas Pipeline Facility

BYHALIA, Mississippi, United States

Overview

Trunkline Gas Company LLC operates a gas pipeline relay facility near Byhalia, Mississippi, supporting the proposed I-269 project. This operational asset is part of the U.S. natural gas transmission network.

Trunkline Gas Company LLC's TGCS Relay for Proposed I-269 is a natural gas pipeline facility located on Peach Tree Road in Byhalia, Marshall County, Mississippi. The facility supports the proposed Interstate 269 project and is part of the broader U.S. natural gas transmission infrastructure. As a relay station, it plays a role in maintaining pressure and flow within the pipeline system. The facility operates under the regulatory oversight of the Pipeline and Hazardous Materials Safety Administration (PHMSA) and complies with 49 CFR Part 192, which governs gas pipeline safety. The NAICS code 486210 indicates it is classified as a natural gas pipeline transmission operation. Typical gas relay stations include valves, metering equipment, and pressure control systems to ensure safe and efficient transport. Located in northern Mississippi, the facility is situated in a region with a mix of rural and developing areas. The proposed I-269 project aims to improve regional transportation, and the pipeline relay supports infrastructure coordination. The facility contributes to the reliability of natural gas supply for residential, commercial, and industrial users in the area, aligning with the sector's role in energy distribution.

Environmental context

The facility is located in Marshall County, Mississippi, an area characterized by rolling hills and agricultural land. Proximity to waterways and populated areas is a consideration for pipeline safety. The transport of natural gas involves risks such as leaks or ruptures, which can impact local ecosystems and communities. Regulatory requirements under PHMSA mandate leak detection, cathodic protection, and emergency response plans to mitigate environmental risks.

Frequently asked questions

The facility is located on Peach Tree Road in Byhalia, Marshall County, Mississippi, USA.

It is a natural gas pipeline relay station that supports pressure regulation and flow control for the Trunkline Gas transmission system, specifically in relation to the proposed I-269 project.

The facility is regulated by the Pipeline and Hazardous Materials Safety Administration (PHMSA) under 49 CFR Part 192, which sets safety standards for gas pipelines.

The NAICS code is 486210, which classifies it as a natural gas pipeline transmission operation.

Typical safety measures include cathodic protection to prevent corrosion, leak detection systems, pressure monitoring, and emergency shutdown valves, all mandated by PHMSA regulations.